Specification of Military Battery BB-590/U Battery(NiCd)
Application for |
PRC-104, PRC-119, PRC-138, KY-57 and other equipment |
Rechargeable or not |
Rechargeable |
Replacement for |
BB-590/U, BA-3590/U, BA-5590/U, BB-490/U, BB-390A/U |
Battery Cell Chemicals |
Nickel Cadmium |
Nominal Voltage |
24 Volts or two 12V sections for alternative connections |
Nominal Capacity |
2.4Ah @ 24V, 4.8Ah @ 12V |
Highest charged voltage |
33 Volts or two 16.5V sections for alternative connections |
Lowest cut-off voltage |
16 Volts or two 8V sections for alternative connections |
Max. charging current |
5A |
Max. continuous discharging current |
12A @ 24V, 24A @ 12V |
Max. pulse discharging current(for 2 second) |
18A @ 24V, 36A @ 12V |
Weight |
1.35kg |
Dimension |
112 x 63 x 125 mm |
Out case materials |
Modified ABS |
Case Safety Guarantee |
Battery has pressure release valve on top |
Shelf life |
To 10 years The battery must be charged at least once every 6 months |
Cycle Life |
500 cycles @ 80% DOD |
Self-discharge rate |
Less than 15% per month |
Maintenance cautions |
The battery must be charged at least once every 6 months |
Storage temperature |
-30℃ to 60℃ |
Performance temperature |
-40℃ to +60℃ |
Battery voltage test |
Passed |
Battery Capacity test |
Passed |
Short-circuit safety |
Passed |
Drop test |
Passed |
Vibration test |
Passed |
Thermo Shock test |
Passed |
Electrolyte Leakage test |
Passed |
Insulation test |
Passed |
Explosion Safety test |
Passed |
Puncture Safety test |
Passed |
Over-thermo protection |
Passed |
Transportation |
Can be shipped by sea shipment and air shipment |
Battery Disposal |
Must be disposed of without any secondary pollution to environment |